+ 86-574-88452652
In domo / Productus / Solenoidal Valvulae

Solenoidal Valvulae

  • Electromagnetic valvae ad continue variabilis tradenda
    Electromagnetic valvae ad continue variabilis tradenda
    Electromagnetic valvae ad continue variabilis tradenda

    Electromagnetic valvae ad continue variabilis tradenda

    Parametri \ exemplar

    Maximum operating oleum pressura

    Current Rating

    Rated voltage

    Lineamentum

    Maximum operating frequency

    Maximum operating temperatus

    Service vitae

    Operantes

    Voltage regulant range

    Proportionalem relevium valvulae

    10Pa

    1.7a

    12V

    ≤3%

    10Hz

    -40 ~ CXXV ℃

    > (XXX) Horae

    X ~ 60l / min

    0,4 ~ 4.5 MPA
    Proportionalem pressura reducendo valvulae

    10Pa

    1.7a

    12V

    ≤3%

    10Hz

    -40 ~ CXXV ℃

    > (XXX) Horae

    X ~ 60l / min

    0 ~ 2.5 MPA

    Parametri \ exemplar

    Maximum operating oleum pressura

    Current Rating

    Rated voltage

    Coil resistentia

    Maximum operating frequency

    Maximum operating temperatus

    Service vitae

    Vestibulum opus traffic

    Solenoid in / off valvulae

    3MPA

    0.7a

    12V

    17,6 Europi

    Non minus quam 25hz

    -40 ~ CXXV ℃

    Numerus Switching> I × X 7 temporum

    Power-in rei publicae: Imperium Portus fluunt Rate 3.5 ± 0.3l / min

    Summus celeritas in / off valvulae

    3MPA

    3.2A

    12V

    3,85 nummorum

    Non minus quam 25hz

    -40 ~ CXXV ℃

    Numerus Switching> I × X 7 temporum

    Power-in rei publicae: Imperium Portus fluxus Rate 3.5 ± 0.3l / min

    ×
  • CDC-I inpulsa absorption ratio solenoid valvae
    CDC-I inpulsa absorption ratio solenoid valvae
    CDC-I inpulsa absorption ratio solenoid valvae

    CDC-I inpulsa absorption ratio solenoid valvae

    ×
  • Internum inpulsa-absorbing solenoid valvae sn61 seriem
    Internum inpulsa-absorbing solenoid valvae sn61 seriem
    Internum inpulsa-absorbing solenoid valvae sn61 seriem

    Internum inpulsa-absorbing solenoid valvae sn61 seriem

    ×
  • Externum inpulsa, absorbing solenoid valvae sn62 seriem
    Externum inpulsa, absorbing solenoid valvae sn62 seriem
    Externum inpulsa, absorbing solenoid valvae sn62 seriem

    Externum inpulsa, absorbing solenoid valvae sn62 seriem

    ×
  • Externum inpulsa, absorbing solenoid valvae sn63 seriem
    Externum inpulsa, absorbing solenoid valvae sn63 seriem
    Externum inpulsa, absorbing solenoid valvae sn63 seriem

    Externum inpulsa, absorbing solenoid valvae sn63 seriem

    ×
  • Aeris Suspensio distribution valvae duo modo valvae
    Aeris Suspensio distribution valvae duo modo valvae
    Aeris Suspensio distribution valvae duo modo valvae

    Aeris Suspensio distribution valvae duo modo valvae

    ×
  • Steering calces solenoid valvae sn901
    Steering calces solenoid valvae sn901
    Steering calces solenoid valvae sn901

    Steering calces solenoid valvae sn901

    ×
  • Steering calces solenoid valvae sn902
    Steering calces solenoid valvae sn902
    Steering calces solenoid valvae sn902

    Steering calces solenoid valvae sn902

    ×
  • Steering calces solenoid valvae sn903
    Steering calces solenoid valvae sn903
    Steering calces solenoid valvae sn903

    Steering calces solenoid valvae sn903

    ×
  • Aeris Suspensio distribution valvae Quinque Via CYMBALON
    Aeris Suspensio distribution valvae Quinque Via CYMBALON
    Aeris Suspensio distribution valvae Quinque Via CYMBALON

    Aeris Suspensio distribution valvae Quinque Via CYMBALON

    Nomen

    Valvulae dispensare

    Product Model

    T5300

    Applicabiles exempla

    Q7, africokee, panamera, cayenne, tourareeg, Tesia
    Jeep Grand Cherolcee
    OE CMLVIII CCCLVIII CMIII 00,68087233aa, 7p0 DCXCVIII 014,970 CCCLVIII CLIII II

    Nomen

    Valvulae dispensare

    Product Model

    T5200

    Applicabiles exempla

    Audi A6, A8D4, A7New Novum Models

    OE 4H0 616,013.4h 0,616.039

    Nomen

    Valvulae dispensare

    Product Model

    T5100

    Applicabiles exempla

    Audi A6c6 A8D3 A6cj A6c5 Volkswagen Phaeton

    OE DCXVI 4f0 XIII

    Nomen

    Valvulae dispensare

    Product Model

    T5400

    Applicabiles exempla

    Renault Vel Terra III, inventa IV, range Rover EXSECUTOR campaign

    OE

    Nomen

    Valvulae dispensare

    Product Model

    T5500

    Applicabiles exempla

    Mercedes Benz W164, W166, W212, W221, W211, W511

    OE A2123200358, A2513200058, A09932000,1643201204
    ×
De nobis
Ningbo Yinzhou tonly hydrau electrica fabrica
Ningbo Yinzhou Tonly Hydraulic Electrical Factory

Ningbo Yinzhou Tonly Hydraulic Electrical Factory In MCMLXXXIX statutum est, quod est professio manufacturer de variis in / off et proportionalem solenoids Hydraulica. Factory est 10000m2. Thereinto, Architecture Covers 7000m2. The factory owns advanced high-precision CNC lathes, an automatic stitch welding machine, a BMC plastic package machine controlled by PLC, a plastic injection molding machine, a solenoid features tester, a solenoid tube oil-pressure-resistant test stand, a solenoid tube pulse fatigue test stand, an excitation coil parameters, and other testers. Per importat, absorbentem et technica upgrading. In praesens, habemus annua productionem facultatem 2,4 million pieces of hydrau solenoids. Omnes products producuntur secundum J. / T5244-2001, VDE0580 Latin quod satiat International Advanced Technical Requisita. Et perficientur est certa et qualis est stabilis. Matched cum Rexroth Type, Northman Type, Yuken Type et Vickers Type, quod products potest late applicari in machine Tools, Plastics Machinery, Telecommunications, Suetia, Korea, Taiwan, et aliis regionibus et regiones.

Certificatorium honoris
  • Certificatorium
  • Certificatorium
  • Certificatorium
  • Certificatorium
  • Certificatorium
  • Certificatorium
  • Certificatorium
  • Certificatorium
  • Certificatorium
  • Certificatorium
Nuntium
Nuntius videre
Industria scientia

I. Quam eligere solenoid ad solenoidal valvulae ad aptet ad diversas voltages et frequentiis?

Discriptis solenoid lumen Solenoidal Valvulae Est momenti gradus ad curare lenis operationem de systematis, quod requirit considerans multiple key factores in occursum specifica voltage et frequency requisita.

Solenoid selenoid valvulae oportet opus recte intra speciem intentione range. Communis voltages includit vexillum alterna current (n) voltages ut 24Vac, 110vac, 220vac et directum current (DC) voltages ut 12VDC et 24VDC. Voltages diversis applicationem missionibus, ita cum eligens opus confirmare voltage range quod solenoid valvae potest accipere firmum operationem ratio.

Frequentia solenoid plane alterius considerari, quod plerumque refert ad frequentiam alternitates current, ut 50hz et 60hz. Cum lectio solenoid coil, oportet ut aequet frequency virtutis copia vitare solenoid valvulae non operantes proprie vel quod laedi ex tempore ad frequency mismatch. Antequam acquisitionem, vos postulo ut diligenter review technica specificationem sheet of solenoid valvae et eligere solenoid coil exemplar quod aequet applicationem requisita.

Praeterea, vos postulo ut consideramus current demanda de solenoid coil. In current consummatio de solenoid sleigon directe afficit potestas consummatio et stabilitatem systematis. Ideo necesse est ut delectae solenoid seligini potest providere stabilis current, cum opus ad curare normalis operationem solenoidal valvulae.

Sub specialem environmental condiciones, ut altum temperatus environments, specialiter disposito solenoid vel non requiritur, uti magno temperatus resistant tortor materiae ad curare diu-term stabilis perficientur. In addition, quidam applications potest postulo ut considerans electro compatibility (EMC) ad vitare electromagnetic litigantium ex intercedendo cum aliis ambiente electronic apparatu.

Sicut core pars solenoidal valvulae, solenoid seligio directe afficit operating efficientiam et stabilitatem ratio. Per diligenter aestimandis applicationem requisitis, eligens ius solenoid coil canendo ut solenoid valvae potest operari fideliter in variis industriae et automation applications, ita improving in altiore efficientiam et perficientur ratio.

II. Quam ad integrate solenoid valvulae cum plc vel DS in Automation Systems?

Integrationem Solenoidal Valvulae Cum plc (programmable logica controller) vel DS (distributed imperium system) in automation systems est a key gradum in processus of Achieving fluidi imperium et automation. Hoc integration involves electrica hospites inter solenoidal valvae et imperium ratio, control ratio programming, signum tradenda, feedback machinationes et salus et diagnostic munera.

Electrical Wiring de Solenoidal valvulae est ex integration. De more, in potestate terminals (ut coil terminals) de Solenoidal valvulae connexae ad digital output modules de plc vel DCS per filis. Hoc dat plc vel DS mittere an aperta vel clausa imperium signum ad solenoidal valvae, ita achieving precise imperium fluidi imperium.

Per integrationem processus, in programming de ratione ratione est ipsum. Per programming software (ut scalam logicam, munus obstructionibus diagram, etc), oportet control ratio potest scriptum determinare cum aperire vel claudere solenoidam valvae. Haec logica plerumque fundatur in propria input conditionibus vel eventus triggers, quae potest consequi altus automated processus imperium.

Signum Transmissus est aliud key factor. In digital signum generatae per output moduli de plc vel DS est traducitur ad imperium terminatio de solenoidal valvulae per fila ad trigger ad actiones solenoidal valvae. In aliqua applications, feedback signa sunt et requiritur ex solenoidal valvulae ad confirmandas sive solenoidal valvulae feliciter switched civitatibus. Haec feruntur significationibus plerumque adeptus per locum switch et sensorem solenoid valvae et pavit ad plc vel DCS per input moduli ulterius processus in control ratione.

Per efficaciter integrationem solenoid valvulae in PLC vel DCS, altus praecise imperium fluidi imperium et automation processibus potest effectum, improvidus productionem efficientiam et uber qualitas dum reducendo operating costs. Hoc integrationem potest obviam necessitatibus variis industriae et automation applications et providere firmum et certa operatio spondet pro ratio.